Green building design optimization to maximize daylight use and reduce associated heat gains in tropical climates.   Detailed 3D modelling of an industrial facility was performed in south and north of Vietnam, which included a sensitivity analysis based on the following parameters:

  • Building orientation
  • Height of the lateral fenestration above floor
  • Window to wall ratio
  • Window to roof ratio
  • Shape of the roof